This program lets you
quantify that error. If you
don't
know the reflection
coefficients, but you do have the VSWR, use the
Utilities+ Ref/MM/VSWR program
first to convert VSWR to reflection coefficient
magnitude. Press
BACK on your browser to return to
this page.
Assume that we have a VSWR = 1.35 source driving a VSWR = 1.5 load.
The reflection coefficients of the source and load are, respectively,
0.15 and 0.2. What is the mismatch uncertainty?
To find the uncertainty, enter the "
S,L Ref."
reflection data as "
.15,.2" at the prompt
up above, and then press
<Enter>.
Here is the output calculation:
+ Error = 0.257 dB
- Error = -0.265 dB