smith.jpg    microwave software®
swoosh.jpg
Utilities+® User Manual
RF/Microwave Design Utility Programs
 


T-LINE Z TRANSFORMATION



                 T-Line Z Transformation

                 This program calculates the input Z of a lossless transmission
                  line given the Z0, electrical line length, theta, and the load
                 Z = RL +j XL.

                 Units: ohms,degrees

                 Enter Z0,Theta,RL and XL  [<Enter>=Quit] ? _


util17.jpg


This program is very easy to use, just enter the four parameters asked for above, each separated by a comma, and press <Enter>.

As an example, consider a 50 ohm transmission line that is a quarter-wave, (90 degrees), long at its operating frequency. If the load impedance is 75+j10, what is the input impedance?

Input "50,90,75,10" at the prompt up above and then press <Enter>.

Here is the output calculation:

                 Rin = 32.751 ohms
                 Xin = -j4.367

Press <Enter> to return to the Main Menu.

Utilities+ User Manual Table of Contents