L-MATCH
NETWORKS
In general, there are
four
two-element networks. However, in actual practice, usually only two are
realizable. The sketch below identifies a
Type 1
and a
Type 2 form. Each creates
two
circuits.
L-Match Networks
Given the source and load impedance, calculate reactance
values for impedance match networks.
Enter Load Z (RL,XL) [<Enter>=Quit] ? _ |
Let's match a 50 ohm source to a 100+j20 load. In answer
to the
above question, enter "
100,20"
(make sure you put a
comma
between the two numbers) and press
<Enter>.
Next input "
50,0" and press
<Enter>
again.
Here is the Type 1 circuit calculation:
Ckt #1:
X1 = 123.923 ohms, X2 = -51.962 ohms
Ckt #2: X1 =
-83.923 ohms, X2 = 51.962 ohms